Skip to Content
Airrex HWC-60R Water-Cooled Portable Spot Cooler 61000 BTU 5 Ton R-454B Refrigerant 220V Single Phase Dual 5 Inch Nozzles Built-In Condensate Pump No Venting Required ETL Listed

Price:

12,442.90

We're Online
Mon–Fri 9am–5pm · Sat 9am–3pm EST
Airrex HSC-18R Portable Spot Cooler 16800 BTU 1.5 Ton R-454B Refrigerant 115V Dual 5 Inch Nozzles 5 Gallon Tank NEMA 5-20 ETL Listed
Airrex HSC-18R Portable Spot Cooler 16800 BTU 1.5 Ton R-454B Refrigerant 115V Dual 5 Inch Nozzles 5 Gallon Tank NEMA 5-20 ETL Listed
4,212.90
4,212.90
Airrex & Flagro AHSC-140R 220/3 Portable Air Conditioner with Heaters 145000 BTU Cooling 100000 BTU Heating
Airrex & Flagro AHSC-140R 220/3 Portable Air Conditioner with Heaters 145000 BTU Cooling 100000 BTU Heating
35,672.76
35,672.76

Airrex HWC-60R Water-Cooled Portable Spot Cooler 61000 BTU 5 Ton R-454B Refrigerant 220V Single Phase Dual 5 Inch Nozzles Built-In Condensate Pump No Venting Required ETL Listed

Similar Products
Need help with this product?
Mon–Sat 9am–5pm EST
Commercial Water-Cooled Spot Cooler

Airrex HWC-60R Water-Cooled Portable Spot Cooler — 61,000 BTU, 5-Ton, R-454B

The Airrex HWC-60R is a heavy-duty 5-ton water-cooled portable spot cooler engineered for high-demand directed cooling in spaces where warm air venting isn't an option. Unlike air-cooled spot coolers, it uses a closed-loop water cooling system to remove condenser heat — making it ideal for industrial production facilities, large enclosed kitchens, and high-ambient environments. Delivers 61,000 BTU of cooling through two 5-inch front cold air nozzles, uses modern R-454B refrigerant, runs on 220V single-phase service (NEMA 5-15 plug, 15-amp circuit), and includes a built-in condensate pump as standard. ETL listed.

61,000 BTU
Cooling Capacity
5 TON
Spot Cooling
R-454B
Refrigerant
220V 1Ph
Water-Cooled
Why It Performs

Key Features

Engineered for dependable performance with the features that matter most.

Water-Cooled, No Venting Required

A closed-loop water cooling system removes condenser heat without warm air discharge — perfect for tightly enclosed spaces where ducting isn't practical or possible.

61,000 BTU Directed Cooling

Heavy-duty 5-ton spot cooling output through dual 5" front cold air nozzles — concentrated cooling for hot work zones in spaces that can't vent.

Dual 5" Cold Air Nozzles

Two front-mounted 5" diameter cold air nozzles let you split airflow between two work zones or aim both at a single hot spot for concentrated cooling.

Eco-Friendly R-454B Refrigerant

Modern low-GWP R-454B refrigerant — the newer-generation "R" model meets current environmental standards while delivering 5 tons of reliable cooling.

Built-In Condensate Pump

Auto condensate pump is included as standard — continuous moisture removal without manual tank emptying, even under heavy dehumidification loads.

ETL Listed & Protected

ETL listed with high/low-pressure switches, 3-minute compressor delay, thermostat protector, fan motor protection, and safety devices for reliable operation.

Note: The HWC-60R is engineered to operate with a closed water loop system — it requires a constant supply of cooling water through twist-and-lock connections. Particularly suited to environments where outdoor exhaust ducting is impossible or where ambient temperatures exceed what air-cooled units can handle. Operating range 68-113°F.

Where It Works

Ideal Applications

Heavy-duty 5-ton water-cooled spot cooling for the most challenging enclosed environments — industrial production, sealed clean rooms, and large institutional kitchens.

Hospitals & Healthcare FacilitiesNo warm air discharge into clinical areas — ideal for surgical suites, treatment rooms, and other healthcare zones where air quality is critical.
Large Production KitchensHeavy-duty spot cooling in large institutional and hotel kitchens where running exterior exhaust ducts isn't practical.
Industrial Production FloorsConcentrated 5-ton worker comfort cooling in enclosed manufacturing zones where air-cooled exhaust would overwhelm the space.
Office ComplexesSelf-contained 5-ton cooling for large interior office spaces, conference centers, and data rooms without exterior wall access.
Clean Rooms & Sealed IndustrialSealed manufacturing zones, pharma cleanrooms, and other spaces where warm-air discharge would compromise the environment.
High-Ambient EnvironmentsSpecifically designed for environments where surrounding temperatures challenge what air-cooled units can handle reliably.
The Details

Specifications

ModelAirrex HWC-60R
Cooling TypeWater-cooled (no venting required)
Cooling Capacity61,000 BTU/h
RefrigerantR-454B (low-GWP)
Power Supply220V, 1 Phase, 60 Hz
Current Consumption12.6 A
Power Consumption (Rated Cooling)1.5 kW
Compressor Input1.45 kW
Motor Input0.18 kW
Circuit Breaker Size15 A
NEMA Plug5-15
Power Cord Length9.8 ft
Operating Conditions72°F DB / 60% RH to 113°F DB / 40% RH
Cooling Operating Range68°F to 113°F
Indoor Airflow (Evaporator, High / Low)450 / 400 CFM
Cold Air DischargeTwo 5" diameter front nozzles
Water CoolingClosed-loop water condenser
Water ConnectionsTwist-and-lock water inlet / outlet
Air FilterAluminum (washable)
Outlet Air Velocity37-42 m/s
Outlet Temp. Difference50-59°F
Static Pressure426 Pa
Max Duct Length30 ft
Condensate PumpIncluded (built-in auto)
SafetyHigh/low pressure switches, 3-min compressor delay, thermostat protector, fan motor protection
Dimensions (W × D × H)17.7" × 22.8" × 42"
Net Weight163 lbs
MobilityFour 4" swivel casters (2 locking)
CertificationETL Listed
Warranty1 year unit, 3 years compressor
Backed by a 1-Year Unit / 3-Year Compressor Warranty
Heavy-duty water-cooled spot cooling, ETL listed, and full Airrex compressor coverage — engineered for the toughest enclosed environments.
Good to Know

Frequently Asked Questions

Why choose a water-cooled spot cooler over an air-cooled one?

Water-cooled is the right choice when you can't vent warm air: tightly enclosed spaces, sealed clean rooms, hospitals, indoor kitchens without exterior wall access, or environments where ambient temperatures challenge what air-cooled exhaust systems can handle.

What's the cooling capacity?

61,000 BTU/h of directed cooling (5-ton) through two 5" front cold air nozzles. Operating range 68-113°F ambient.

What power does the HWC-60R need?

220V single-phase, 60 Hz service through a NEMA 5-15 plug on a 15-amp circuit. The water-cooling system makes it electrically efficient — just 12.6 A current draw at 1.5 kW.

What refrigerant does the HWC-60R use?

Modern, low-GWP R-454B refrigerant. The "R" suffix indicates this updated refrigerant generation versus the older HWC-60 (R-410A) — this is a fully refreshed model.

Is the condensate pump built in?

Yes. The HWC-60R includes a built-in auto condensate pump as standard — continuous moisture removal without manual tank emptying.

How does the water cooling work?

The HWC-60R uses a closed-loop water system — water circulates through the condenser to absorb heat, then returns to a chiller, cooling tower, or building water loop to dissipate that heat. Twist-and-lock water inlet/outlet connections make hookup straightforward.

Brand Airrex & Flagro
https://www.usaequipmentdirect.com/web/image/product.template/14921/image_1920?unique=8705163

12,442.90 12442.9 USD 12,442.90

Call for Help Website Price Call Us For More Information !

  • Brand

This combination does not exist.

  • [Price Match Guarantee] Price Match Guarantee
    Price Match Request
    Find better pricing? Just send it to us and ask for a quote!
  • Financing

    Financing Available, Flexible payment plans to fit your budget. Click here to explore your options

  • Guaranteed Safe Checkout

    Guaranteed Safe Checkout

SKU HWC-60R
Brand Airrex & Flagro
Airrex & Flagro Logo