Airrex HSC-60R 220/1 Portable Spot Cooler 60000 BTU 5 Ton R-454B Refrigerant 220V Single Phase Dual 8 Inch Nozzles Built-In Condensate Pump ETL Listed
Airrex HSC-60R 220/1 Portable Spot Cooler — 60,000 BTU, 5-Ton, R-454B
The Airrex HSC-60R 220/1 is a heavy-duty 5-ton portable spot cooler engineered for high-demand directed cooling in large commercial and industrial spaces. With 60,000 BTU of cooling, two 8-inch front cold air nozzles for high-volume directed airflow, and a 16-inch top warm air exhaust, it tackles the biggest spot-cooling jobs that fit a 220V single-phase circuit. Uses modern R-454B refrigerant (8.38 lbs charge), runs on 220V single-phase with a 50-amp fuse, and includes a built-in condensate pump as standard. ETL listed. Operating range 65-118°F.
Key Features
Engineered for dependable performance with the features that matter most.
60,000 BTU Directed Cooling
5-ton cooling capacity at 95°F/40% — built for the biggest single-circuit spot-cooling jobs, with operating range up to 118°F ambient.
Dual 8" Cold Air Nozzles
Two front-mounted 8" diameter cold air nozzles deliver high-volume directed airflow — split between two zones or stack both on a single hot spot.
R-454B Refrigerant (8.38 lbs)
Modern low-GWP R-454B refrigerant charge — meets current environmental standards while delivering 5 tons of reliable spot cooling.
Built-In Condensate Pump
Auto condensate pump is included as standard — no manual tank emptying. Handles up to 88.8 gal/day max dehumidification load.
Four Locking Casters
Four 5" swivel casters with all four locking — roll the 628 lb unit into position, then lock it down securely for stable operation.
ETL Listed & Protected
ETL listed with high/low-pressure switches, 3-minute compressor delay timer, thermostat protector, fan motor protection, and tank shut-off.
Note: The HSC-60R 220/1 operates from 65-118°F ambient. The 16" top warm air exhaust supports an optional warm air duct kit (8 ft of ducting + 2'x2' ceiling flange). For tightly enclosed spaces, fresh air supply may be needed for optimal performance. An optional HEPA filter kit is available for the HSC-36R/60R/70R series.
Ideal Applications
5-ton directed spot cooling for the biggest commercial and industrial jobs that 220V single-phase can power.
Specifications
| Model | Airrex HSC-60R 220/1 |
|---|---|
| Cooling Capacity | 60,000 BTU/h |
| Refrigerant | R-454B (8.38 lbs, low-GWP) |
| Power Supply | 220V, 1 Phase, 60 Hz |
| Voltage Range | 187-242 V |
| Current (Cooling) | 27.3 A |
| Power Consumption | 5.92 kW |
| Fuse Size | 50 A |
| Cooling Operating Range | 65°F to 118°F |
| Dehumidification (Max / Nominal) | 88.8 / 62.6 gal/day |
| Indoor Airflow | 1,850 CFM |
| Outdoor Airflow | 3,020 CFM |
| Cold Air Discharge | Two 8" diameter front nozzles |
| Warm Air Discharge | 16" diameter top flange |
| Max Equivalent Duct Length (Outdoor) | 70 ft |
| Air Filters | Aluminum + Stainless Mesh (removable, washable, both sides) |
| Sound Level (With Exhaust Duct / Without) | 63 / 65 dB(A) |
| Condensate Pump | Included (built-in) |
| Safety | High/low pressure switches, 3-min compressor delay, thermostat protector, fan motor protection, auto tank shut-off |
| Dimensions (W × D × H) | 29" × 54" × 57" |
| Net Weight | 628 lbs |
| Mobility | Four 5" swivel casters (4 locking) |
| Certification | ETL Listed |
| Warranty | 1 year unit, 3 years compressor |
Frequently Asked Questions
What power does the HSC-60R 220/1 need?
The HSC-60R 220/1 runs on 220V single-phase, 60 Hz service with a 50-amp fuse required. Current draw is 27.3 A at 5.92 kW. Verify electrical service before ordering.
What's the cooling output?
60,000 BTU/h of directed cooling (5-ton) through two 8" front cold air nozzles. Operates in ambient temperatures up to 118°F.
Is the condensate pump built in?
Yes. The HSC-60R 220/1 includes a built-in auto condensate pump as standard. Built to handle dehumidification loads up to 88.8 gal/day (max) without manual tank emptying.
What refrigerant does the HSC-60R 220/1 use?
Modern, low-GWP R-454B refrigerant with an 8.38 lb charge. The "R" suffix indicates this updated refrigerant generation versus the older HSC-60 (R-410A).
What's the difference between the 220/1, 220/3, and 460/3 versions?
Same 5-ton cooling capacity and R-454B refrigerant. 220/1 = single-phase 220V (50A fuse), 220/3 = 220V 3-phase (30A fuse), 460/3 = 460V 3-phase (15A fuse). Choose based on the electrical service available at your site.
How portable is the HSC-60R 220/1?
It weighs 628 lbs and rolls on four 5" swivel casters with all four locking. Once in position, lock the casters for stable operation. Best moved by two people on level surfaces.
| Brand | Airrex & Flagro |
-
Price Match Request
Find better pricing? Just send it to us and ask for a quote! -
Financing Available, Flexible payment plans to fit your budget. Click here to explore your options
-
Guaranteed Safe Checkout
| SKU | HSC-60R 220/1 |
| Brand | Airrex & Flagro |
|
|