Skip to Content
Airrex HSC-60R 220/1 Portable Spot Cooler 60000 BTU 5 Ton R-454B Refrigerant 220V Single Phase Dual 8 Inch Nozzles Built-In Condensate Pump ETL Listed

Price:

12,608.83

We're Online
Mon–Fri 9am–5pm · Sat 9am–3pm EST
Airrex AF 2300 Portable Axial Air Mover 1932 CFM 22 Inch Fan 1.4 Amp 115V 4 Operating Positions ETL/CSA Listed
Airrex AF 2300 Portable Axial Air Mover 1932 CFM 22 Inch Fan 1.4 Amp 115V 4 Operating Positions ETL/CSA Listed
436.39
436.39
Airrex HSC-60R 220/3 Portable Spot Cooler 60000 BTU 5 Ton R-454B Refrigerant 220V 3-Phase Dual 8 Inch Nozzles Built-In Condensate Pump ETL Listed
Airrex HSC-60R 220/3 Portable Spot Cooler 60000 BTU 5 Ton R-454B Refrigerant 220V 3-Phase Dual 8 Inch Nozzles Built-In Condensate Pump ETL Listed
13,322.32
13,322.32

Airrex HSC-60R 220/1 Portable Spot Cooler 60000 BTU 5 Ton R-454B Refrigerant 220V Single Phase Dual 8 Inch Nozzles Built-In Condensate Pump ETL Listed

Similar Products
Need help with this product?
Mon–Sat 9am–5pm EST
Commercial Portable Spot Cooler

Airrex HSC-60R 220/1 Portable Spot Cooler — 60,000 BTU, 5-Ton, R-454B

The Airrex HSC-60R 220/1 is a heavy-duty 5-ton portable spot cooler engineered for high-demand directed cooling in large commercial and industrial spaces. With 60,000 BTU of cooling, two 8-inch front cold air nozzles for high-volume directed airflow, and a 16-inch top warm air exhaust, it tackles the biggest spot-cooling jobs that fit a 220V single-phase circuit. Uses modern R-454B refrigerant (8.38 lbs charge), runs on 220V single-phase with a 50-amp fuse, and includes a built-in condensate pump as standard. ETL listed. Operating range 65-118°F.

60,000 BTU
Cooling Capacity
5 TON
Spot Cooling
R-454B
Refrigerant
220V 1Ph
Single Phase
Why It Performs

Key Features

Engineered for dependable performance with the features that matter most.

60,000 BTU Directed Cooling

5-ton cooling capacity at 95°F/40% — built for the biggest single-circuit spot-cooling jobs, with operating range up to 118°F ambient.

Dual 8" Cold Air Nozzles

Two front-mounted 8" diameter cold air nozzles deliver high-volume directed airflow — split between two zones or stack both on a single hot spot.

R-454B Refrigerant (8.38 lbs)

Modern low-GWP R-454B refrigerant charge — meets current environmental standards while delivering 5 tons of reliable spot cooling.

Built-In Condensate Pump

Auto condensate pump is included as standard — no manual tank emptying. Handles up to 88.8 gal/day max dehumidification load.

Four Locking Casters

Four 5" swivel casters with all four locking — roll the 628 lb unit into position, then lock it down securely for stable operation.

ETL Listed & Protected

ETL listed with high/low-pressure switches, 3-minute compressor delay timer, thermostat protector, fan motor protection, and tank shut-off.

Note: The HSC-60R 220/1 operates from 65-118°F ambient. The 16" top warm air exhaust supports an optional warm air duct kit (8 ft of ducting + 2'x2' ceiling flange). For tightly enclosed spaces, fresh air supply may be needed for optimal performance. An optional HEPA filter kit is available for the HSC-36R/60R/70R series.

Where It Works

Ideal Applications

5-ton directed spot cooling for the biggest commercial and industrial jobs that 220V single-phase can power.

Large Manufacturing & ProductionHigh-capacity spot cooling for production lines, paint booths, welding stations, and large assembly areas with concentrated heat.
Industrial Sites & PlantsCar manufacturing, shipbuilding, steel mills, and other high-temperature work sites where workers need targeted relief.
Large Commercial Kitchens3-zone cooling for major hotel and institutional kitchens with multiple cook lines, hood areas, and prep stations.
Server Rooms & Data CentersBackup or supplemental cooling for medium-to-large server rooms when central HVAC fails or is overloaded.
Event Venues & OutdoorHeavy-duty portable cooling for large tented events, hotel ballrooms, and outdoor venues with serious BTU demand.
Warehouses & DistributionSpot cooling for warehouse workstations, loading docks, and large back-of-house operations.
The Details

Specifications

ModelAirrex HSC-60R 220/1
Cooling Capacity60,000 BTU/h
RefrigerantR-454B (8.38 lbs, low-GWP)
Power Supply220V, 1 Phase, 60 Hz
Voltage Range187-242 V
Current (Cooling)27.3 A
Power Consumption5.92 kW
Fuse Size50 A
Cooling Operating Range65°F to 118°F
Dehumidification (Max / Nominal)88.8 / 62.6 gal/day
Indoor Airflow1,850 CFM
Outdoor Airflow3,020 CFM
Cold Air DischargeTwo 8" diameter front nozzles
Warm Air Discharge16" diameter top flange
Max Equivalent Duct Length (Outdoor)70 ft
Air FiltersAluminum + Stainless Mesh (removable, washable, both sides)
Sound Level (With Exhaust Duct / Without)63 / 65 dB(A)
Condensate PumpIncluded (built-in)
SafetyHigh/low pressure switches, 3-min compressor delay, thermostat protector, fan motor protection, auto tank shut-off
Dimensions (W × D × H)29" × 54" × 57"
Net Weight628 lbs
MobilityFour 5" swivel casters (4 locking)
CertificationETL Listed
Warranty1 year unit, 3 years compressor
Backed by a 1-Year Unit / 3-Year Compressor Warranty
Heavy-duty 5-ton spot cooling, ETL listed, and full Airrex compressor coverage — built for major commercial and industrial jobs.
Good to Know

Frequently Asked Questions

What power does the HSC-60R 220/1 need?

The HSC-60R 220/1 runs on 220V single-phase, 60 Hz service with a 50-amp fuse required. Current draw is 27.3 A at 5.92 kW. Verify electrical service before ordering.

What's the cooling output?

60,000 BTU/h of directed cooling (5-ton) through two 8" front cold air nozzles. Operates in ambient temperatures up to 118°F.

Is the condensate pump built in?

Yes. The HSC-60R 220/1 includes a built-in auto condensate pump as standard. Built to handle dehumidification loads up to 88.8 gal/day (max) without manual tank emptying.

What refrigerant does the HSC-60R 220/1 use?

Modern, low-GWP R-454B refrigerant with an 8.38 lb charge. The "R" suffix indicates this updated refrigerant generation versus the older HSC-60 (R-410A).

What's the difference between the 220/1, 220/3, and 460/3 versions?

Same 5-ton cooling capacity and R-454B refrigerant. 220/1 = single-phase 220V (50A fuse), 220/3 = 220V 3-phase (30A fuse), 460/3 = 460V 3-phase (15A fuse). Choose based on the electrical service available at your site.

How portable is the HSC-60R 220/1?

It weighs 628 lbs and rolls on four 5" swivel casters with all four locking. Once in position, lock the casters for stable operation. Best moved by two people on level surfaces.

Brand Airrex & Flagro
https://www.usaequipmentdirect.com/web/image/product.template/14929/image_1920?unique=3268ab6

12,608.83 12608.83 USD 12,608.83

Call for Help Website Price Call Us For More Information !

  • Brand

This combination does not exist.

  • [Price Match Guarantee] Price Match Guarantee
    Price Match Request
    Find better pricing? Just send it to us and ask for a quote!
  • Financing

    Financing Available, Flexible payment plans to fit your budget. Click here to explore your options

  • Guaranteed Safe Checkout

    Guaranteed Safe Checkout

SKU HSC-60R 220/1
Brand Airrex & Flagro
Airrex & Flagro Logo
Resources

Document