Skip to Content
Airrex HSC-60R 220/3 Portable Spot Cooler 60000 BTU 5 Ton R-454B Refrigerant 220V 3-Phase Dual 8 Inch Nozzles Built-In Condensate Pump ETL Listed

Price:

13,322.32

We're Online
Mon–Fri 9am–5pm · Sat 9am–3pm EST
Airrex HSC-60R 220/1 Portable Spot Cooler 60000 BTU 5 Ton R-454B Refrigerant 220V Single Phase Dual 8 Inch Nozzles Built-In Condensate Pump ETL Listed
Airrex HSC-60R 220/1 Portable Spot Cooler 60000 BTU 5 Ton R-454B Refrigerant 220V Single Phase Dual 8 Inch Nozzles Built-In Condensate Pump ETL Listed
12,608.83
12,608.83
Airrex HSC-60R 460/3 Portable Spot Cooler 60000 BTU 5 Ton R-454B Refrigerant 460V 3-Phase Dual 8 Inch Nozzles Built-In Condensate Pump ETL Listed
Airrex HSC-60R 460/3 Portable Spot Cooler 60000 BTU 5 Ton R-454B Refrigerant 460V 3-Phase Dual 8 Inch Nozzles Built-In Condensate Pump ETL Listed
13,322.32
13,322.32

Airrex HSC-60R 220/3 Portable Spot Cooler 60000 BTU 5 Ton R-454B Refrigerant 220V 3-Phase Dual 8 Inch Nozzles Built-In Condensate Pump ETL Listed

Similar Products
Need help with this product?
Mon–Sat 9am–5pm EST
Commercial Portable Spot Cooler

Airrex HSC-60R 220/3 Portable Spot Cooler — 60,000 BTU, 5-Ton, R-454B, 3-Phase

The Airrex HSC-60R 220/3 is a heavy-duty 5-ton portable spot cooler engineered for high-demand directed cooling in commercial and industrial spaces with 220V 3-phase electrical service. Same 5-ton cooling output and 8" dual-nozzle design as the 220/1 model — but with the lower current draw (18.5 A vs 27.3 A) and smaller fuse requirement (30 A vs 50 A) that 3-phase service makes possible. Uses modern R-454B refrigerant (8.38 lbs), includes a built-in condensate pump, and ships ETL listed.

60,000 BTU
Cooling Capacity
5 TON
Spot Cooling
R-454B
Refrigerant
220V
3-Phase
Why It Performs

Key Features

Engineered for dependable performance with the features that matter most.

60,000 BTU Directed Cooling

5-ton cooling capacity at 95°F/40% — high-volume spot cooling for industrial sites with 220V 3-phase service, operating up to 118°F ambient.

Dual 8" Cold Air Nozzles

Two front-mounted 8" diameter cold air nozzles deliver concentrated, high-volume directed airflow for serious spot-cooling jobs.

3-Phase Efficiency

220V 3-phase reduces current draw to just 18.5 A (vs 27.3 A on the 220/1 single-phase version), requiring only a 30-amp fuse and smaller wiring.

R-454B Refrigerant (8.38 lbs)

Modern low-GWP R-454B refrigerant — meets current environmental standards while delivering 5 tons of reliable spot cooling.

Built-In Condensate Pump

Auto condensate pump is included as standard — handles up to 88.8 gal/day max dehumidification load without manual tank emptying.

ETL Listed & Protected

ETL listed with high/low-pressure switches, 3-minute compressor delay, thermostat protector, fan motor protection, and tank shut-off.

Note: The HSC-60R 220/3 requires 220V 3-phase service — not a standard single-phase outlet. Operating from 65-118°F ambient. The 16" top warm air exhaust supports an optional warm air duct kit. An optional HEPA filter kit is available for the HSC-36R/60R/70R series.

Where It Works

Ideal Applications

5-ton directed spot cooling for industrial sites with 220V 3-phase power — manufacturing, plants, and major commercial operations.

Manufacturing & ProductionHigh-capacity 3-phase cooling for production lines, paint booths, welding stations, and assembly areas in industrial facilities.
Industrial Plants & MillsCar manufacturing, shipbuilding yards, steel mills, and other 3-phase facilities where workers need targeted cooling.
Large Commercial Kitchens3-zone cooling for major hotel, casino, and institutional kitchens with 3-phase electrical service.
Server Rooms & Data CentersBackup cooling for medium-to-large server rooms in facilities with 3-phase power infrastructure.
Warehouses & PlantsSpot cooling for warehouse workstations, plant offices, and back-of-house operations with 3-phase hookups.
Auto, Ship & Steel YardsHeavy industrial spot cooling for the demanding environments where 3-phase service is standard.
The Details

Specifications

ModelAirrex HSC-60R 220/3
Cooling Capacity60,000 BTU/h
RefrigerantR-454B (8.38 lbs, low-GWP)
Power Supply220V, 3 Phase, 60 Hz
Voltage Range187-242 V
Current (Cooling)18.5 A
Power Consumption5.98 kW
Fuse Size30 A
Cooling Operating Range65°F to 118°F
Dehumidification (Max / Nominal)88.8 / 62.6 gal/day
Indoor Airflow1,850 CFM
Outdoor Airflow3,020 CFM
Cold Air DischargeTwo 8" diameter front nozzles
Warm Air Discharge16" diameter top flange
Max Equivalent Duct Length (Outdoor)70 ft
Air FiltersAluminum + Stainless Mesh (removable, washable, both sides)
Sound Level (With Exhaust Duct / Without)63 / 65 dB(A)
Condensate PumpIncluded (built-in)
SafetyHigh/low pressure switches, 3-min compressor delay, thermostat protector, fan motor protection, auto tank shut-off
Dimensions (W × D × H)29" × 54" × 57"
Net Weight628 lbs
MobilityFour 5" swivel casters (4 locking)
CertificationETL Listed
Warranty1 year unit, 3 years compressor
Backed by a 1-Year Unit / 3-Year Compressor Warranty
5-ton spot cooling for 220V 3-phase service, ETL listed, full Airrex compressor coverage — efficient cooling for industrial facilities.
Good to Know

Frequently Asked Questions

What's the difference between 220/1 and 220/3?

Same 5-ton capacity and R-454B refrigerant. The 220/3 version uses 3-phase 220V service for lower current draw (18.5 A vs 27.3 A) and smaller fuse (30 A vs 50 A). Choose based on whether your facility has 3-phase hookups.

Will the HSC-60R 220/3 run on single-phase 220V?

No. The HSC-60R 220/3 requires 220V 3-phase service. For single-phase 220V hookups, choose the HSC-60R 220/1 model instead.

What's the cooling output?

60,000 BTU/h of directed cooling (5-ton) through two 8" front cold air nozzles. Operating range 65-118°F ambient.

Is the condensate pump built in?

Yes. The HSC-60R 220/3 includes a built-in auto condensate pump as standard, handling up to 88.8 gal/day max dehumidification load.

What refrigerant does the HSC-60R 220/3 use?

Modern, low-GWP R-454B refrigerant with an 8.38 lb charge. The "R" suffix indicates this updated refrigerant generation versus older R-410A versions.

Is HEPA filtration available?

Yes. An optional HEPA filter kit is available for the HSC-36R/60R/70R series — useful for jobsites or healthcare environments needing extra filtration.

Brand Airrex & Flagro
https://www.usaequipmentdirect.com/web/image/product.template/14930/image_1920?unique=3268ab6

13,322.32 13322.32 USD 13,322.32

Call for Help Website Price Call Us For More Information !

  • Brand

This combination does not exist.

  • [Price Match Guarantee] Price Match Guarantee
    Price Match Request
    Find better pricing? Just send it to us and ask for a quote!
  • Financing

    Financing Available, Flexible payment plans to fit your budget. Click here to explore your options

  • Guaranteed Safe Checkout

    Guaranteed Safe Checkout

SKU HSC-60R 220/3
Brand Airrex & Flagro
Airrex & Flagro Logo
Resources

Document